Installation Instructions

The areawall should extend beyond the window
rough opening by 3” both sides. Some building codes
may require additional clearance. The top of the areawalls
should extend approximately 2” above the established
grade line and down at least 12” below the windowsill.
If in doubt, go with a higher wall since extensions are
difficult to attach. Fill the space below the window well
with select gravel for drainage. Flanges should be attached
to the foundation wall at sufficient points (12” centers
minimum) to assure structural stability. Use masonry nails,
self-drilling anchors or other approved fasteners. Select
backfill material should be used, such as granular with
some clay that is free of large rock and earth clods and
should not be frozen material, sod, cinders or other active
soils. The load carrying capacity of the areawalls is largely
dependent upon proper backfill procedure. The fill should
be placed evenly around the areawall in 12” layers
using ordinary compaction making sure the shape is not distorted.
On larger sizes a 90 % density factor may be desirable.
Compacted fill around the outside of the areawall should
be at least 12”, or one-half of areawall projection.
We recommend supporting the areawall inside face during
the backfilling procedure. Supports should be left in place
until construction activity ceases. On larger and deeper
areawalls, care should be used in selecting the grade and
style.